10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision

显示的图像仅供参考,从产品数据表中获得准确的规格。
10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision
型号: 10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision
品牌:
封装:
年份: new+
描述: 10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision
库存: 9999 Pieces
发货时间: 1-2 天
数据手册:
如果您需要获得更多的价格,请将您的RFQ发送至 info@hfd-ic.com

产品介绍

10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision 最优惠价格 和快速交付.
恒锋达是10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision的经销商,我们有库存可立即发货,也可长期供应。请通过电子邮件将您的10A Digital Temperature Humidity Controller SHT20 DC 6V-30V high precision购买计划发送给我们,我们将根据您的计划为您提供最优惠的价格。
我们的电子邮件:info@hfd-ic.com

产品描述

PRODUCT DESCRIPTION

10A Thermostat Digital Temperature Humidity Controller DC 6V-30V Thermal Regulator Thermocouple LCD Display SHT20 Sensor meter

Product Description:

XY-WTH1 Temperature and humidity control module high precision digital displayword double output automatic constant temperature and humidity control panelProduct adopts industrial-grade chip, high-precision SHT20 temperature andhumidity sensor.

 

FUNCTION
Product features are two main types of classification: the functions of temperatureand humidity;
FUNCTION OF TEMPERATURE ARE AS FOLLOWS
1. The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode
Start temperature > stop temperature, cooling mode C
Start temperature < stop temperature, heating mode H

 

2. Cooling mode:
When the temperature 2 Start temperature, relay conduction, red led on, refrigerationequipment begin to work,
When the temperature s Stop temperature, relay disconnect, red led off, refrigerationequipment stop to work;


3. Heating mode:
When the temperature s Start temperature, relay conduction, red led on, heatingequipment begin to work;
When the temperature 2 Stop temperature, relay disconnect, red led off, heatingequipment stop to work;


4. emperature correction function OFE(-10.0~10℃):
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value


How to set the start/stop temperature:
1. In the running interface, Long Press TM+ key more than 3 seconds, into thestart temperature settings interface, can be modified by TM+ TM- key, to be modified. waiting for 6s automatic exit and save,
2. In the running interface, Long Press TM- key more than 3 seconds, into thestop temperature settings interface, can be modified by TM+ TM- key, to be modifiedafter the parameters, waiting for 6s automatic exit and save;


THE HUMIDITY FUNCTIONIS AS FOLLOWS

 

1. The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode:Start humidity> stop humidity, dehumidification mode D
Start humidity< stop humidity, humidification mode E!


2. Dehumidification mode:
When the humidity> Start humidity, relay conduction, green led on, dehumidificationequipment begin to work;
When the humiditys Stop humidity, relay disconnect, green led off, dehumidificationequipment stop to work;


3. Humidification mode:
When the humiditys Start humidity, relay conduction, green led on, humidificationequipment begin to work;
4. Humidification correction function RH (-10.0~10%)
The system is working for a long time and may be biased, through this functioncorrection, the actual humidity = measuring humidity + calibration value:


How to set the start/stop humidity:
1. In the running interface, Long Press RH+ key more than 3 seconds, into thestart humidity settings interface, can be modified by RH + RH - key, to be modified. waiting for 6s automatic exit and save,
2. In the running interface, Long Press RH- key more than 3 seconds, into thestop humidity settings interface, can be modified by RH+ RH- key, to be modifiedafter the parameters, waiting for 6s automatic exit and save.


Running Interface Description:
Working mode shows that the current mode ("H/C",E/d") will be synchronized atthe front of temperature/humidity, when the setting of temperature/humidity andstop temperature/humidity are completed.
Any relay conduction, the upper-left corner of the interface display "out", if thetemperature relay conduction, the flashing display temperature working mode "H/Cto show reminders; if the humidity relay conduction, then flashing display humidityworking mode "E/d", as a reminder;


How to enable/disable relay:
In the running interface, Short press TM- key, enable/disable the temperature relay(ON: enable OFF: disable), back to the running interface, if the temperature relay isdisable, the temperature symbol flashes to remind.
In the running interface, Short press RH- key, enable/disable the humidity relay(ON: enable OFF: disable), back to the running interface, if the humidity relay isdisable, the humidity symbol % flashes, as a reminder.
Serial control(TTL level)
Baud Rate:9600bps Data bits :8
stop bits :1crc :none
Flow control :none
CMD        Description
Start        Start data upload
stop         Stop data upload
read         Read the param setting
T:ON        Temperature relay enable
T:OFF       Temperature relay disable
H:ON        Humidity relay enable
H:OFF       Humidity relay disable
TS:XX.X     Set start Temperature (-20.0~60.0)
TP:XX.X     Set stop Temperature (-20.0~60.0)
HS:XX.X    Set start Humidity (00.0~100.0)
HP:XX.X    Set stop Humidity(00.0~100.0)
TC:XX.X     Set Temperature Calibration (-10.0~10.0)
HC:XX.X    Set Humidity Calibration (-10.0~10.0)

 

Temperature and humidity Data upload format Description:
Temperature format: Operating mode (H/C), temperature value, temperature relay status;

Humidity Format: Operating mode (E/D), humidity value, humidity relay status;

H,20.5°,CL : Heating operating mode, the current temperature of 20.5 degrees.temperature relay disconnection state,
D,50.4%,OP : Dehumidification working mode, current humidity 50.4%, humidityrelay connection;

 